How to become a COOL SMART QIV participating contractor in three easy steps!

COOLSMART QIV SealWhat is QIV?
Quality Installation Verification (QIV) service checks for and reports on optimal refrigerant charge and system air flow. After a residential customer central A/C installation, a QIV participating technician tests the system and takes a series of measurements. COOL SMART provides a QIV certificate that is mailed to the customer, providing third-party verification that your technician properly adjusted charge and airflow.

Step One: Getting Started (or you can elect to go right to Step Two)

Sign up for a FREE one hour QIV Tool Demo. During this demonstration, two advanced diagnostics systems/tools will be presented: Check Me! By Proctor Engineering and the Honeywell Service Assistant (HSAT). At the end of the demo, we will work with you to help you decide which platform will best fit your company's needs.

ACTION: Visit www.fielddiagnostics.com for HSAT and www.proctoreng.com for
CheckMe! to select a platform.

Step Two: QIV Training

During this step, technicians complete COOL SMART-sponsored QIV training. As part of a limited time offer, training only costs $125. For hands-on instruction, you must have all the required equipment and indicate the QIV platform you will be using. QIV training must be completed prior to participating. Register now for QIV training

ACTION: Contact Agnes Hagopian at (508) 836-9500 ext. 13213.

Step Three: Enjoy the Perks!

After attending QIV training and performing three successful installations that pass the QIV standards, your training fee will be reimbursed, plus you will receive up to $150 toward the purchase of a digital thermometer or hot-wired anemometer. In addition, there is a QIV Incentive of $175 for each system which passes charge and airflow tests and is properly reported to COOL SMART.

"Quality" is More Than Just a Word - You Can Demonstrate it With QIV!
Charge can only be set properly with respect to airflow which is not usually checked. Incorrect charge and/or incorrect airflow reduce energy efficiency which often lead to unwanted callbacks. With QIV you can check charge and airflow dynamically and stay ahead of your competition!

slugged compressor

By implementing Quality Installation Verification services you can:

  • Gain customer trust and referrals by proving your job is a quality installation through third-party verification
  • Reduce callbacks and time spent on troubleshooting
  • Increase technician productivity
  • Set yourself apart from the competition
  • Get a head start on a growing national trend that the EPA will be promoting

Additional Perks!

  • QIV Incentive of $175 for each system which passes charge and airflow tests and is properly reported to COOL SMART
  • Listing as QIV service provider on COOL SMART website
  • Marketing of QIV service in yellow pages and other media
  • Customer literature describing the need for and value of QIV
  • Reimbursement for hands-on QIV field training after three QIV "passes" by technician


Click on the logos below for sponsor information